ABB PowerValue 11 RT 3kVA B 1 Phase Rack Mount UPS
This Model Has Been Discontinued
Contact For The Best Replacement
Call: +971-4-3360300 | Email: [email protected]
The ABB PowerValue 11 RT 3 kVA B is a true online/double‑conversion UPS designed to deliver clean, uninterrupted power for critical single‑phase IT and communication systems. With a 3 kVA / 2.7 kW rating, this model protects servers, storage devices, network equipment, and sensitive electronics from mains disturbances such as surges, sags, noise, and outages.
PRODUCT OVERVIEW
ABB PowerValue 11 RT 3 kVA B UPS
The ABB PowerValue 11 RT 3 kVA B is a true online/double‑conversion UPS designed to deliver clean, uninterrupted power for critical single‑phase IT and communication systems. With a 3 kVA / 2.7 kW rating, this model protects servers, storage devices, network equipment, and sensitive electronics from mains disturbances such as surges, sags, noise, and outages. It is engineered for both rack‑mount (2 RU) and tower configurations, giving installers flexibility in deployment.

Electrical Performance and Power Quality
This UPS uses online double‑conversion (VFI‑SS‑111) topology to continuously condition incoming mains power, delivering a pure sine‑wave output with tight voltage regulation (± 1 % referred to 230 V) and low distortion under load. The unit supports a broad input voltage range (208 / 220 / 230 / 240 VAC) and frequency tolerance (45–55 Hz / 54–66 Hz), making it tolerant of unstable utility conditions. Its output power rating of 2.7 kW (0.9 power factor) ensures efficient real‑world power delivery to connected loads.

Battery Backup and Runtime Features
The PowerValue 11 RT 3 kVA B includes built‑in valve-regulated lead‑acid (VRLA) batteries, enabling essential backup power during grid outages. Typical backup time at full rated load is approximately 4 minutes, suitable for graceful shutdowns or short interruptions; actual runtime varies with load and configuration. The unit supports external battery modules (EBMs) to scale runtime further for longer outages or critical load requirements. Recharge time to 90 % battery capacity is typically around 3 hours under normal conditions.
Feature Highlights
- True online double conversion (VFI) UPS – single phase input / single phase output.
- Rack-tower convertible (90-degree rotating display).
- Best in class double conversion efficiency up to 98% to minimise energy loss.
- Optimised for modern IT loads with rated output power factor up to 1.0 (unity).
- Thinnest single phase UPS on the market at only 2 RU (rack units).
- Flexible configurations for scalable runtime by including external battery modules (EBM).
- Adjustable DC voltage and battery charger current.
- Optional external maintenance bypass with PDU (power distribution unit).
- Full range of connectivity options and accessories for remote monitoring and interfacing.
| Product Name | ABB PowerValue 11 RT 3kVA B 1 Phase Rack Mount UPS |
|---|---|
| Output Power | 3KVA/ 3000VA |
| Output Voltage | 240 Volts |
| Input Frequency | 45-55 Hz / 54-66 Hz |
| Input Voltage Range | 208 / 220 / 230 / 240 VAC |
| Interface Ports | RS-232, SNMP slot, USB |
| Control Panel | Rotatable LCD Display |
| Battery Type | VRLA, vented lead-acid |
| Recharge Time | 3 hours to 90% |
| Audible Alarm | -- |
| Cord Length | -- |
| Approvals | Safety= IEC/EN 62040-1, EMC= IEC/EN 62040-2, Performance= IEC/EN 62040-3, Manufacturing= ISO 9001:2008, ISO 14001:2004. |
| Dimensions | 438 x 86.5 x 608mm |
| Shipping Dimensions | 438 x 86.5 x 608mm |
| Weight | 12.972742 |
| Shipping Weight | 28.6 |
| Manufacturer | ABB |
| Color | Black |
| Country of Origin | United Arab Emirates |